  fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 11/46 h.v. distribution equipment instrument transformers zct, evt and special purpose ct description fuji can supply special purpose cts, zcts (zero-phase current transformers) and evts (earthing voltage transformers) as well as standard fuji instrument transformers. some of the versions are described below. ced and zced the ced and zced are split- construction types.they can be mounted in position without disconnecting the cables. ced: epoxy-molded split-toroidal type ct zced: epoxy-molded split-toroidal type zct zce zce type is toroidal-type zcts and molded in epoxy resin. gve and gpe gve and gpe series are 3-phase earthing voltage transformers. gve: epoxy-molded type (3.3kv, 6.6kv) gpe: epoxy-molded type (11 to 33kv) note: all types are for indoor use only. type number nomenclature ?toroidal type zct zce  a/  basic type zce: epoxy molded toroidal type zced: epoxy molded split-toroidal type hole diameter, mm 1: 65 4: 125 (zce type) 2: 80 (zce type) 130 (zced type) 90 (zced type) 5: 190 (zce type) 3: 100 150 (zced type) rated primary current (amps.): 200 to 1500 ?split-toroidal type ct ced  /  basic type hole diameter, mm 1: 65 2: 90 3, 3a, 3b: 100 4: 130 rated primary current (amps) 200 to 3000 ?earthing voltage transformer evt gpe  -  f -  basic type gve, gpe: epoxy-molded type secondary rated burden gve gpe: 1: 3 x 100va 21: 3 x 200va 2: 3 x 200va 13: 3 x 200va 12: 3 x 200va 9: 3 x 200va 8: 3 x 200va 7: 3 x 200va(400a) rated primary voltage 3: 3.3kv 10: 11kv 20: 22kv 6: 6.6kv 15: 13.2kv 30: 33kv rated secondary voltage toroidal type zct zce2a split-toroidal type ct ced2 cp-622 cp-620 earthing voltage transformer gve1 cp-619 toroidal type zct description hole primary rated zero-phase rated overcurrent type diameter current current (ma) burden constant (mm) (a) primary secondary ( ? )(n 0 ) indoor use 65 0 200 200 1.5 10 n 0 > 2000 zce1a/200 80 0 400 zce2a/400 epoxy molded 100 0 750 zce3a/750 toroidal type 125 0 1200 zce4a/1200 190 0 3000 zce5a/3000 indoor use 65 0 200 200 1.5 10 n 0 > 2000 zced1/200 90 0 400 zced2/400 epoxy molded 100 0 600 zced3/600 split-toroidal 130 0 750 zced4/750 type 150 0 1500 zced5/1500 ( ) available on request
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 11 11/47 h.v. distribution equipment instrument transformers split-toroidal type ct hole diameter primary current (a) secondary rated overcurrent type (mm) single ratio double ratio current (a) burden (va) constant (n) 65 200 5 15 n > 10 ced1/200 300 15 ced1/300 400 25 ced1/400 500 25 ced1/500 600 40 ced1/600 750 40 ced1/750 90 200 5 15 n > 10 ced2/200 300 25 ced2/300 400 40 ced2/400 500 40 ced2/500 600 40 ced2/600 750 40 ced2/750 1000 5 40 n > 20 ced2/1000 1200 40 ced2/1200 1500 40 ced2/1500 100 300 5 25 n > 10 ced3/300 400 40 ced3/400 500 40 ced3/500 600 40 ced3/600 750 5 40 n > 20 ced3/750 1000 40 ced3/1000 1200 40 ced3/1200 1500 40 ced3/1500 2000 40 ced3/2000 3000 40 ced3/3000 300 300 150 5 25 n > 20 ced3a/300 400 400 200 40 ced3a/400 500 40 ced3a/500 600 600 300 40 ced3a/600 300 300 150 5 40 n > 20 ced3b/300 130 400 400 200 5 40 n >10 ced4/400 500 40 ced4/500 600 600 300 40 ced4/600 750 5 40 n > 20 ced4/750 800 400 40 ced4/800 1000 1000 500 40 ced4/1000 1200 1200 600 40 ced4/1200 1500 1500 750 40 ced4/1500 2000 2000 1000 40 ced4/2000 3000 3000 1500 40 ced4/3000
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 11/48 h.v. distribution equipment instrument transformers earthing voltage transformer evt rated voltage (v) rated burden (va) dielectric strength impulse* 1 type fuse (kv, 1minute) (kv) primary secondary tertiary secondary tertiary primary secondary 3300 110 110 3 100 3 500 2 2 45 gve1-3fa-110/5g ptfa-6* 2 33 200 3 500 2 2 45 gve2-3fa-110/5g 6600 110 110 3 100 3 500 2 2 60 gve1-6fa-110/5g 33 200 3 500 2 2 60 gve2-6fa-110/5g 11000 110 110 3 200 3 200 2 2 90 gpe9-10 jr-10/5* 3 33 200 3 200 2 2 75 gpe8-10 jr-10/5* 3 3 200 3 200 2 2 90 gpe7-10 jr-10/5* 3 13200 110 110 3 200 3 200 2 2 95 gpe7-15 jr-10n/5* 3 3 22000 110 110 3 200 3 200 2 2 125 gpe12-20 jr-20/5* 3 3 22000 110 110 3 200 3 200 2 2 150 gpe13-20 jr-20/5* 3 3 33000 110 110 3 200 3 200 2 2 170 gpe21-30 3 zce5a/3000 dimensions, mm toroidal-type zct zce1a, 2a, 3a,4a type d x y z h w a b mass (kg) zce1a/200 65 140 75 180 110 90 40 25 4.0 zce2a/400 80 160 90 210 130 90 40 25 5.6 zce3a/750 100 185 105 248 155 120 60 35 8.4 zce4a/1200 125 214 120 287 180 120 60 35 12.0 dimensions for reference only. please confirm before construction begins. note: * 1 : 1.2 50 s * 2 : provided * 3 : optional k x z h w a 20 10 3.2 20 b test terminal 2-m5 secondary terminal 2-m5 np y 135 175 2- 15 l d k kt lt 310 k 355 180 200 190 test terminal m5 secondary terminal m5 160 200 25 40 25 100 l 2- 15 3.2 k kt lt mass: 14kg
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 11/49 11  dimensions, mm  split-toroidal type ct/zced  earth voltage transformer vt/gve1, gve2 type x y z a b c d e f g h i j k m n mass (kg) zced1 260 95 225 100 125 130 65 27 30 135 175 2 14 m10 3.2 27 15 zced2 310 110 270 120 150 150 90 27 40 135 175 2 14 m10 4.5 27 20 zced3 340 110 295 130 165 150 100 30 40 135 175 2 14 m10 4.5 27 25 zced4 380 140 350 155 195 200 130 30 55 200 250 4 18 m10 6 30 30 zced5 460 150 405 185 220 200 150 30 55 200 250 4 18 m12 6 30 52 dimensions for reference only. please confirm before construction begins. type x y z d a 1 a 2 b 1 b 2 cefn ced1 95 260 225 65 260 80 220 125 27 57 2 ced2 110 310 285 90 300 90 260 165 27 82 2 ced3 110 340 295 100 300 95 260 165 27 67 2 ced3a 200 340 295 100 300 190 260 120 165 50 65 4 ced3b 250 340 295 100 300 240 260 120 165 50 65 4 ced4 125 350 305 130 300 110 260 70 165 50 50 4 dimensions for reference only. please confirm before construction begins.  split-toroidal type ct/ced secondary terminal m5 tertiary terminal m5 primary neutral terminal m6 bb u v a b v u v a b v u v a b v fuse primary terminal m6 4- 12 f f+40 y uuu (u) (v) (w) np (3-phase) np (single-phase) a u (u) uv u (v) uv u (w) uv uvwabcf 0 0 uv ab uv ab uv ab cd z e c x x k 4-k l c e f a z b zced4,5 mounting hole secondary terminal 2-m5 test terminal 2-m5 100 d g h m i- j np y k kt lt n 110 np 4-m10 y d k c z 3.2 b1 a1 secondary terminal m5 np mounting hole n- 14 kl l x b2 a2 e f type x y z a b c d e f mass (kg) gve1 428 265 284 136 146 104 220 90 220 59 gve2 476 305 300 152 162 128 220 100 220 82 dimensions for reference only. please confirm before construction begins.
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 11/50  dimensions, mm h.v. distribution equipment instrument transformers gpe12-20  earthing voltage transformer vt (with fuse links) gpe9-10 gpe7-10, gpe7-15 gpe8-10 gpe13-20 gpe21-30 mass: 160kg earth terminal m8 primary neutral terminal m6 85 10 4- 12 220 35 20 301 95 416 20 3 name plate 3 phase name plate 452 226 226 566 160 295 135 160 160 134 260 6 40 143 153 126 vv v v u v u uuu a b v u a b v u a b ua vb v ua vb v u uuu a vb v 320 467 50 6 320 260 350 20 900 350 310 560 secondary and tertiary terminal m6 neutral terminal m8 2-m8, depth 15 lifting lug 14 160 u u v a b u v a b u v a b uuu vv v vw 170 160 135 290 primary neutral terminal m6 fuse 170 35 10 500 260 252 160 460 4- 12 m6 220 262 95 20 320 40 6 377 35 410 a b u v a b u v a b u v 770 lifting lug 300 350 4- 14 455 475 315 275 275 773 u u u 223 140 20 98 6 6 25 183 385 50 95 530 m6 m8 10 226 226 35 452 680 310 350 360 377 135 225 4- 14 280 95 20 a b u v a b u v a b u uu u v vvv 50 425 6 10 fuse secondary and tertiary terminal m6 primary neutral terminal m8 6 30 163 mass: 125kg mass: 140kg mass: 76kg mass: 75kg u u u u u u a b u v u v u v v a b v a b v 10 901 535 320 560 310 350 510 95 6 6 415 195 148 25 50 4- 14 320 225 160 310 261 75 35 20 m8 earth terminal m8 lifting lug mass: 190kg


▲Up To Search▲   

 
Price & Availability of CED1400

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X